Change Language Change Language
www.daikin-ce.com
 

Basic Information PDF Export
Technical Solution VRV ®
Address Bul. Aleksandar Makedonski 22
City Skopje
Request Flexible operation, cost effective and reliable system which can provide both heating and cooling in the entire building was the main request of the beneficiary.
Solution Due to efficiency, energy savings, easy maintenance and environmental friendly properties, designers have chosen Daikin VRV system.
Building Text The Yahya Kemal Private College is a modern building consisting of several units reflecting the highest standards and most modern architectural designs.
Application Type Combined System
Construction Type New Buldings

Technical Information
Total Surface m² 4000
Total AC Surface m² 4000
Cooling capacity kW 432,9 kW
Number / Type of Indoor Units 1: FXMQ250M, FXCQ40M, FXCQ32M, FXDQ63N, FXDQ40N, FXDQ25M, FXDQ20M, FXZQ20M; 4: FAQ100B, FXZQ50M; 6: FXFQ63M; 2: FXDQ50N, FXAQ63M; 9: FXZQ40M; 12: FXAQ50M; 17: FXAQ40M; 6: FXAQ32M; 33: FXAQ25M; 6: FXAQ20M; 1: VAM1000; 2: VAM800, VAM500; 4: VAM250; 12: VAM150; 1: DAM602A52
Number / Type of Outdoor Units 1: RXYQ8MY1B, RXYQ10M; 3: RXYQ14M; 5: RXYQ16M; 2: RZQ200B;
Indoor Unit Application
CassetteCeiling susp.Concealed CeilingDuctedFloorWall
Consultant (Designer) Spiro Atanasoski, Vlatko Spirovski
Architect Pane Balvanliev
Installer VAKO
Investor SMEKI company
Link http://www.yahyakemalcollege.edu.mk