Change Language Change Language
www.daikin-ce.com
 

Basic Information PDF Export
Technical Solution VRV ®
Address Listopadska 2
City Zagreb
Request High efficiency system for cooling. Low investment cost. Reduced energy consuption and operating costs.
Solution VRV I was choosen for covering cooling loads, but also for heating in spring and autumn. Different centralized heating system is used separately. All outdoor units are placed inside the roof thanks to big external static pressure available on fans. Ducted system for each fan has been implemented. Even the outdoor units of VRV system can be used also for indoor installation!
Building Text Among the most modern of its type in Zagreb, this imposing 6 storey building is home to a successful insurance company. Conceived along ultra modern lines, the complex features a visually striking pillared reception hall, high cellings, prestigious finishes, generous working space for its occupants and a wide range of desirable office amenities.
Application Type Office
Construction Type New Buldings

Technical Information
Cooling capacity kW 340kW
Number / Type of Indoor Units 39/FVKS-K, 24/FXYM-K, 14/VAM-EJ
Number / Type of Outdoor Units 4/RXY30K
Indoor Unit Application
CassetteCeiling susp.Concealed CeilingDuctedFloorWall
Control System 1/D-Bacs
Options
Consultant (Designer) Klimaproing
Architect
Installer
Investor Koncern Agram
Link http://www.jadransko.hr/podruznice/zagreb.html