| Technical Solution | VRV ® | ||
| Address | Soseaua de centura 41, comuna Chiajna, Jud. Ilfov | ||
| City | Bucharest | ||
| Request | The air conditioning installation should ensure the thermal comfort parameters for showroom areas, office areas and common areas. The flexibility and power reduced consumption were the main requirements for the air conditioning system. The installation and commissioning works had to be carried out in a short period of time following the quality conditions imposed by the Austrian beneficiary. Another requirement was to reduce the noise level as much as possible and to ensure a high level of comfort especially in the office areas and the public relations areas. | ||
| Solution | To ensure all required conditions for the air conditioning system as well as to carry out the installation with little disturbance of the hotel activity, there was proposed and chosen the solution based on the Daikin VRV heat pump air conditioning system. The inner units chosen for the showroom area can be connected to the piping, with air distribution through grids and anemostates. The system ensures an efficient control of the air conditioning parameters per each and every device, per groups of devices or per areas. Both in the office area and the common areas, the inner units were mounted on decorative panel ceilings or floor units. | ||
| Building Text | Built on over 8000 sqm, Porche Bucharest North comprises three showrooms, a service station with high-end equipped machine and electric repair shop, tin shop and dye house, spare parts deposit, ITP station and an automatic car wash. | ||
| Application Type | Store & Shop | ||
| Construction Type | New Buldings | ||
| Commissioning Date | 2002 | ||
| Technical Information | |||||||
| Total AC Surface m² | 2580 | ||||||
| Cooling capacity kW | 270 | ||||||
| Heating capacity kW | 290 | ||||||
| Number / Type of Indoor Units | 4/FXYLP50,1/FXYMP250,3/FXMP200,6/FXYMP125, 2/FXYSP50,1/FXYSP80,2/FXYCP80,1/FDY200,1/FT45 | ||||||
| Number / Type of Outdoor Units | 3/RSXYP30, 1/RY200,1/R45D | ||||||
| Indoor Unit Application |
|
||||||
| Control System | Centralized control | ||||||
| Options | Fresh air for offices area. | ||||||
| Consultant (Designer) | Domoterm | ||||||
| Architect | Porsche Romania | ||||||
| Installer | Integral Technic Trade | ||||||
| Investor | Porsche Romania | ||||||
| Link | http://www.pbn.ro/ | ||||||
Porsche Nord
|
||||||